    10KV And 35KV Cable Testing Machine, High Voltage Ac Testing Equipment

    Ask Lasest Price
    Brand Name : Ningbo Suntech Power
    Model Number : CHX-405KVA/27KV,54KV
    Certification : ISO9001
    Price : Negotiable
    Payment Terms : T/T
    Supply Ability : 10units/1months
    Delivery Time : 25-30 Work Days
    • Product Details
    • Company Profile

    10KV And 35KV Cable Testing Machine, High Voltage Ac Testing Equipment

    Portable Variable Frequency Resonant Withstand Voltage Test Set , For 10KV and 35KV Cable Test


    I. Product Usage :


    This test set model CHX-405KVA/27KV, 54KV is designed for 10KV and 35KV class XLPE cable on-site AC withstand voltage test with variable frequency resonant circuit technology; the highest test voltage is no more than 22KV or 52KV; test frequency: 30-300Hz; the duty cycle is no more than 60mints. it can help customers to perform preventive test or hand-over test on AC withstand voltage test for XLPE cables 35KV within 3km and 10KV class within 7km .

    Test range of the set is as following:

    1. 3km of 35kV/300mm2 cable, tested capacitance ≤0.5835uF, test frequency 30-300Hz, test voltage 52kV, test time 60min.

    2, 7km of 10kV/300mm2 cable , tested capacitance ≤ 2.62uF, test frequency 30-300Hz, test voltage 22kV, test time 5min.


    II. General Technical Data


    1. Rated capacity: 405kVA;
    2. Input power: three-phase 380V voltage, frequency is 50Hz;
    3. Rated voltage: 27kV; 54kV;
    4. Rated current: 15A; 7.5A;
    5. Working frequency: 30-300Hz;
    6. Device output waveform: sine wave
    7. Waveform distortion rate: output voltage waveform distortion rate ≤ 1%;
    8. Working time: continuous 60min allowed under rated load; overpressure 1.1 times 1 minute;
    9. Temperature rise: temperature rise ≤65K after continuous operation for 60 minutes under rated load;
    10. Quality factor: device itself Q≥30 (f=45Hz);
    11. Protection function: Over-current, over-voltage and test product flashover protection for the tested product (see the variable frequency power supply section for details);
    12. Measurement accuracy: system effective value 1.5;


    III. Main Components:


    SNName of ComponentsType and specificationQty.Each weightEach Dimension
    1Variable frequency powerFKVF-30kW/380V1piece35kgs480*480*520mm
    2Excitation transformerCQSB(J)-25kVA/1.5KV,3KV1piece80kgs550*550*580mm
    3HV resonant test reactorCHX(kf)-67.5kVA/27kV/50H10pieces65kgsD480*H520mm
    4Capacitive dividerTRF-60kV/3000pF1set10kgsD150*H650mm
    5Special test accessories1set

    IV. Test priciple :
    10KV And 35KV Cable Testing Machine , High Voltage Ac Testing Equipment 0

    VF: Variable Frequency Power Source T : Excitation Transformer
    L : Test Reactor Cx: Tested Equipment MOA1: Lightning Arrestor
    C1,C2: Voltage divider(C1 is high voltage arm,C2 is low voltage arm )


    V. Main Measuring and control software panel:
    10KV And 35KV Cable Testing Machine , High Voltage Ac Testing Equipment 1
    Note: This is the software panel before start test for parameter setting



    VI.Accessories

    • Accessory box for storage accessoires
    • Input cables of power source
    • Output cables of power source
    • Output cables of exciting transformer
    • System grounding cables
    • Parallel cables of the reactor
    • HV measuring cables ( the signal output cables of voltage divider )
    • HV output cables(reactor to divide,divider to test object)
    • A final test report, a quality Certificate ,a user manual and a packing list are offered .


    VII. Other Optional Model


    1. For GIS on-site test

    ModelRated voltageRated output currentRated output capacity

    Application

    (From 45Hz starting)

    CHX-135KVA/135KV27KV*51A135KVAFor 72.5KV and below GIS
    CHX-270KVA/135KV27KV*51A135KVAFor 72.5KV and below GIS
    CHX-216KVA/216KV27KV*81A216KVAFor 123KV and below GIS
    CHX-270KVA/270KV27KV*101A270KVAFor 145KV and below GIS
    CHX-275KVA/275KV275KV2A275KVAFor 170KV and below GIS
    Special requirement can be made by order

    2. For 45KV XLPE cable on-site test

    ModelRated voltageRated output currentRated output capacityMax Application
    CHX-108/5454KV2A108KVA45kV cable≤1km
    CHX-216/5454KV4A216KVA45kV cable≤2km
    CHX-324/5454KV6A324KVA45kV cable≤3km
    CHX-432/5454KV8A432KVA45kV cable≤4km
    CHX-540/5454KV10A540KVA45kV cable≤5km
    CHX-1080/5454KV20A1080KVA45kV cable≤10km
    Special requirement can be made by order

    3. For 66KV XLPE cable on-site test

    ModelRated voltageRated output currentRated output capacityMax Application
    CHX-160/8080KV2A160KVA66kV cable≤0.5km
    CHX-320/8080KV4A320KVA66kV cable≤1km
    CHX-640/8080KV8A640KVA66kV cable≤2km
    CHX-960/8080KV12A960KVA66kV cable≤3km
    CHX-1280/8080KV16A1280KVA66kV cable≤4km
    CHX-1600/8080KV20A1600KVA66kV cable≤5km
    CHX-3200/8080KV40A3200KVA66kV cable≤10km
    CHX-9600/8080KV120A9600KVA66kV cable≤20km
    Special requirement can be made by order

    VIII. On-site insulation test standard table from IEC 60840:2011 for XLPE cable